ScanTek Anleitung CONTENTSPREVNEXTHOME


 History

 V1.0  30 Nov. 1995

   - first public release


 V1.1  17 Dec. 1995

   - detection of Microtek scanner via SCSI inquiry enhanced
   - stepping of resolution slider adapted to expanded base resolution
   - calculation of scanning frame size data modified


 V1.2   3 Jan. 1996

   - Debug output data revised and enhanced
   - Max Frame Setting setting introduced
   - Start of external program possible
   - Window positions are remembered and saved
   - Configuration file enhanced


 V1.3  25 Feb. 1996

   - Detection of new ScanMaker E3 Flatbed scanner implemented
   - Special adaption for E3 to use 8.5 * 13.5 inch scanning frame
     (due to E3 inquiry data the max frame size is 8.5 * 11.69 inch)
   - No start of the external program, if the scanning process is aborted
   - Higher dpi rates for ScanMaker 35t (slide scanner) possible
     Preview image schould look better now.
   - "Main Control" window and gadgets modified
   - Debug filename "ScanTek.log" can be overriden through CLI or Tooltype


 V2.0  30 Apr. 1996

   - Preview in color mode with proper options values
   - Use of expanded Contrast and Exposure Time selections on certain scanners
   - X and Y Aspect Ratio in scanned color images is now correct
   - ScanMaker E3 does not support undocumentated red, gree and blue scanning
   - Lookup Table command supported (Gamma Correction on certain scanner
     possible)
   - Scanning Frame Setting is now more intuitive
   - Reverse image scanning supported (only on certain scanners possible)
   - Accurate scanning frame definition. Scanning frame is now more precise.


 V2.1  5 July 1996

   - Preview now fully supported for Mustek 6000CX
   - Special adaption for Mustek 6000CX to use 8.5 * 14 inch scanning frame


 V2.2 26 July 1996

   - Enhanced support for Mustek scanners
     "Exposure Time" and "Contrast" parameters are now correct
   - Gamma value "All" now works on threepass scanner
   - Alternative Black/White scanning mode


 V2.3  6 Sept. 1996

   - Color Preview on Cybergraphix screens in true color mode (15, 16 or 24 bit)
     for onepass flatbed scanners
   - Grey/Red/Green/Blue Preview on Cybergraphix screens in true color mode
     (15, 16 or 24 bit) for threepass and onepass flatbed scanners
   - Change and recall of predefined resolution values


 V2.4 10 Sept. 1996

   - Support of Mustek SCSI one pass color scanners in color mode and
     parameter ranges.
   - ScanTek can now open its GUI windows on the actual public screen.


 V2.5  5 Oct. 1996

   - Workaround to handle strange color mode behaviour of Mustek
     one pass scanners
   - Reverse scanning in black and white mode introduced


 V2.6  30 Oct. 1996

   - Full support of Mustek one pass scanners
   - Recognition of Mustek scanners enhanced


 V2.7  6 Dec. 1996

   - Recognition and handling of new Mustek scanners enhanced
   - Recognition of Microtek ScanMaker E6 adapted


 V2.8  11 Jan. 1997

   - New icons for ScanTek
   - Recognition and handling of new Mustek scanners enhanced
   - Minior bug fixes
   - Introduction of the ScanTek Support WebSite


 V2.9   9 Feb. 1997

   - Redesign of the Look-Up Table related window


 V2.10 26 Mar. 1997

   - Full size preview on 400 dpi Mustek scanners adjustable


 V3.0  16 Apr. 1997

   - ARexx support
   - XBMI-chunk introduced to store dpi (dots per inch) information in
     IFF File
   - Handling of Microtek ScanMaker E6 enhanced
   - Bugfixes: "Exposure Time" and "Contrast" parameters for Microtek
               and some Mustek scanner models are now correct.
               This bug could lead to images that where to light.
               Grey preview of color image now work with all specified
               settings.


 V3.1  19 May 1997

   - Recognition of Highscreen PerfectScan (600dpi) introduced
   - Recognition of Highscreen RealScan (300dpi) introduced
   - Activation of newly opened windows works now correct


 V3.2  8 June 1997

   - Workaround for surfsquirrel.device to avoid SCSI bus hangup
   - ARexx scripts: Load scanned pictures into 
                    ImageFX:   ST2ImageFX.strx
                    ArtEffect: ST2ArtEffect.strx


 V3.3  1 August 1997

   - Detection of ScanMaker 35t+ introduced 
   - Faster preview scanning process on some scanner models
   - "Accurate Coordinates" support for ScanMaker E6 and compatible


 V3.4  21 October 1997

   - Support of Transparency Adapter (Slide Kit Unit)
   - Prevent system lockup during startup on Dataflyer SCSI+ host
     adapter


 V3.5  4 December 1997

   - Rework of window activation procedures
   - Rework of font sentivity
   - PROGDIR: usage reduced
   - Support of multiple SCSI host adapters in one system


 V3.6  21 December 1997

   - The Mustek MFS-12000SP is now supported
   - Rework of ASL requester handling
   - PROGDIR: usage reduced


 V3.7  30 December 1997

   - Detection of Mustek scanners enhanced
     Erkennung von Mustek Scannern weiterentwickelt

   - German Documentation
     Deutsche Anleitung


 V3.8  23 February 1997

   - Reparatur des Mustek Farbscanprozesses (Fehlerhafte Bilddaten
     im Segentscanmodus)

   - Unterstützung des Durchlichtaufsatzes weiterentwickelt

   - Der erste Versuch in der Unterstützung des europäischen Mustek
     ScanExpress 12000SP und des internationalen Mustek Paragon 1200 IIISP.
     Diese beiden Scanner sind anscheinend identisch.
     Aufgrund gänzlich fehlender Programmierunterlagen ist nur eine
     eingeschränkte Unterstützung möglich:
       ... Graustufenscan ist möglich.
       ... Farbscannen arbeitet nicht korrekt und ist daher unbrauchbar.
     Diese Scannermodelle sind für ScanTek nicht zu empfehlen.
     Wenn es irgentwann in der Zukunft eine Mustek Programmierdokumentation
     für diese Scanner geben wird, dann wird es einen zweiten Versuch
     zur Unterstützung geben.


 V3.9  15 March 1998

   - Erweiterte Unterstützung des europäischen Mustek ScanExpress 12000SP
     und des baugleichen internationalen Mustek Paragon 1200 IIISP.
       Dieses Scanermodell ist aber nicht für den Betrieb mit ScanTek zu
       empfehlen.
       Eine Vorschau ist nun auch bei kleinem Vorschaufenster möglich.
       Farbscannen ist nun möglich, aber nur bei den Auflösungen
       150, 300, 600 und 1200 dpi erfolgreich.
       Desweiteren sind nur kleine Scanbilder erfolgreich.

   - Das neue Microtekmodell ScanMaker E3PLUS ist in der Testphase.
     (siehe Übersicht für Einzelheiten)

   - Microtek V300, 330 und 630 
       Diese Scannermodelle sollten nun auch unterstützt werden, da sie
       laut Programmierdokumentation mit dem Microtek E3PLUS verwandt
       sind.


 V3.10 17 April 1998

   - Der erste Versuch in der Unterstützung des Microtek 330.
     Die Scangeschwindigkeit hängt sehr stark vom verwendeten SCSI Host
     Adapter ab.
     Dieses Scannermodell kann bei kritischen SCSI Host Adaptern zum
     Aufhängen des SCSI Busses (stehenbleiben des Rechners) führen.


 V3.11 24 May 1998

   - Unterstützung des neuen Highscreen HighScan II (Microtek) und
     der neuesten Version des Microtek E3Plus


 V4.0 19 June 1998
 
   - Lokalisierung von ScanTek.
     Unterstützte Sprachen: english, deutsch, dansk

   - Neue email Addresse: scantek@gmx.de, wzoehner@gmx.de


 V4.1 29 August 1998

   - Vollständige Unterstützung der Microtek 630, 330 und des
     Highscreen Highscan II
     - Farbkorrekturtabellen werden nun unterstützt
     - Schnellere Vorschaufunktion bei den neuen Microtekscannern

   - ScanTek Supporthomepage ist umgezogen nach
       http://www.users.odn.de/~odn05111/scantek.html

   - Erweiterte Bildschirmmodusverwaltung bei Programmstart


 V4.2  9 September 1998
 
   - Kataloge zur Lokalisierung werden nun korrekt erneuert

   - Keine Farbverfälschungen mehr, wenn Farbkorreturtabellen bei
     Microtek 630, 330 und Highscreen Highscan II deaktiviert sind


 V4.3  6 Dezember 1998

   - Unterstützung des Durchlichtaufsatzes und Steuerung der Lampen bei
     Microtek 63x, 33x and compatible Highscreen HighScan Scannermodellen


 V4.4  3 February 1999

   - Verbesserte Surfsquirrel SCSI Unterstützung. Neue Microtekscanner
     arbeiten nun auch nach Aktivierung des Surfsquirrel Workarounds.
     Problematische SCSI Hostadapter könnten nun ebenfalls funktionieren.


 V4.5  3 May 1999

   - Ungetestete Unterstützung für neuen Microtek ScanMaker X6


 V4.6 27 January 2002

   - Better support for ScanMaker 45t
   - Dokumentation update (Homepage and eMail)
   - ScanTek support homepage has been moved to
       http://www.zoehner.de/scantek.html

ANFANG Wenn Sie Anregungen oder Fragen zu ScanTek haben, dann schreiben Sie doch an scantek@gmx.de CONTENTSPREVNEXTHOME

Copyright 1996/97/98/2002 by Waldemar Zöhner V1.1