History
V1.0 30 Nov. 1995
- first public release
V1.1 17 Dec. 1995
- detection of Microtek scanner via SCSI inquiry enhanced
- stepping of resolution slider adapted to expanded base resolution
- calculation of scanning frame size data modified
V1.2 3 Jan. 1996
- Debug output data revised and enhanced
- Max Frame Setting setting introduced
- Start of external program possible
- Window positions are remembered and saved
- Configuration file enhanced
V1.3 25 Feb. 1996
- Detection of new ScanMaker E3 Flatbed scanner implemented
- Special adaption for E3 to use 8.5 * 13.5 inch scanning frame
(due to E3 inquiry data the max frame size is 8.5 * 11.69 inch)
- No start of the external program, if the scanning process is aborted
- Higher dpi rates for ScanMaker 35t (slide scanner) possible
Preview image schould look better now.
- "Main Control" window and gadgets modified
- Debug filename "ScanTek.log" can be overriden through CLI or Tooltype
V2.0 30 Apr. 1996
- Preview in color mode with proper options values
- Use of expanded Contrast and Exposure Time selections on certain scanners
- X and Y Aspect Ratio in scanned color images is now correct
- ScanMaker E3 does not support undocumentated red, gree and blue scanning
- Lookup Table command supported (Gamma Correction on certain scanner
possible)
- Scanning Frame Setting is now more intuitive
- Reverse image scanning supported (only on certain scanners possible)
- Accurate scanning frame definition. Scanning frame is now more precise.
V2.1 5 July 1996
- Preview now fully supported for Mustek 6000CX
- Special adaption for Mustek 6000CX to use 8.5 * 14 inch scanning frame
V2.2 26 July 1996
- Enhanced support for Mustek scanners
"Exposure Time" and "Contrast" parameters are now correct
- Gamma value "All" now works on threepass scanner
- Alternative Black/White scanning mode
V2.3 6 Sept. 1996
- Color Preview on Cybergraphix screens in true color mode (15, 16 or 24 bit)
for onepass flatbed scanners
- Grey/Red/Green/Blue Preview on Cybergraphix screens in true color mode
(15, 16 or 24 bit) for threepass and onepass flatbed scanners
- Change and recall of predefined resolution values
V2.4 10 Sept. 1996
- Support of Mustek SCSI one pass color scanners in color mode and
parameter ranges.
- ScanTek can now open its GUI windows on the actual public screen.
V2.5 5 Oct. 1996
- Workaround to handle strange color mode behaviour of Mustek
one pass scanners
- Reverse scanning in black and white mode introduced
V2.6 30 Oct. 1996
- Full support of Mustek one pass scanners
- Recognition of Mustek scanners enhanced
V2.7 6 Dec. 1996
- Recognition and handling of new Mustek scanners enhanced
- Recognition of Microtek ScanMaker E6 adapted
V2.8 11 Jan. 1997
- New icons for ScanTek
- Recognition and handling of new Mustek scanners enhanced
- Minior bug fixes
- Introduction of the ScanTek Support WebSite
V2.9 9 Feb. 1997
- Redesign of the Look-Up Table related window
V2.10 26 Mar. 1997
- Full size preview on 400 dpi Mustek scanners adjustable
V3.0 16 Apr. 1997
- ARexx support
- XBMI-chunk introduced to store dpi (dots per inch) information in
IFF File
- Handling of Microtek ScanMaker E6 enhanced
- Bugfixes: "Exposure Time" and "Contrast" parameters for Microtek
and some Mustek scanner models are now correct.
This bug could lead to images that where to light.
Grey preview of color image now work with all specified
settings.
V3.1 19 May 1997
- Recognition of Highscreen PerfectScan (600dpi) introduced
- Recognition of Highscreen RealScan (300dpi) introduced
- Activation of newly opened windows works now correct
V3.2 8 June 1997
- Workaround for surfsquirrel.device to avoid SCSI bus hangup
- ARexx scripts: Load scanned pictures into
ImageFX: ST2ImageFX.strx
ArtEffect: ST2ArtEffect.strx
V3.3 1 August 1997
- Detection of ScanMaker 35t+ introduced
- Faster preview scanning process on some scanner models
- "Accurate Coordinates" support for ScanMaker E6 and compatible
V3.4 21 October 1997
- Support of Transparency Adapter (Slide Kit Unit)
- Prevent system lockup during startup on Dataflyer SCSI+ host
adapter
V3.5 4 December 1997
- Rework of window activation procedures
- Rework of font sentivity
- PROGDIR: usage reduced
- Support of multiple SCSI host adapters in one system
V3.6 21 December 1997
- The Mustek MFS-12000SP is now supported
- Rework of ASL requester handling
- PROGDIR: usage reduced
V3.7 30 December 1997
- Detection of Mustek scanners enhanced
Erkennung von Mustek Scannern weiterentwickelt
- German Documentation
Deutsche Anleitung
V3.8 23 February 1997
- Reparatur des Mustek Farbscanprozesses (Fehlerhafte Bilddaten
im Segentscanmodus)
- Unterstützung des Durchlichtaufsatzes weiterentwickelt
- Der erste Versuch in der Unterstützung des europäischen Mustek
ScanExpress 12000SP und des internationalen Mustek Paragon 1200 IIISP.
Diese beiden Scanner sind anscheinend identisch.
Aufgrund gänzlich fehlender Programmierunterlagen ist nur eine
eingeschränkte Unterstützung möglich:
... Graustufenscan ist möglich.
... Farbscannen arbeitet nicht korrekt und ist daher unbrauchbar.
Diese Scannermodelle sind für ScanTek nicht zu empfehlen.
Wenn es irgentwann in der Zukunft eine Mustek Programmierdokumentation
für diese Scanner geben wird, dann wird es einen zweiten Versuch
zur Unterstützung geben.
V3.9 15 March 1998
- Erweiterte Unterstützung des europäischen Mustek ScanExpress 12000SP
und des baugleichen internationalen Mustek Paragon 1200 IIISP.
Dieses Scanermodell ist aber nicht für den Betrieb mit ScanTek zu
empfehlen.
Eine Vorschau ist nun auch bei kleinem Vorschaufenster möglich.
Farbscannen ist nun möglich, aber nur bei den Auflösungen
150, 300, 600 und 1200 dpi erfolgreich.
Desweiteren sind nur kleine Scanbilder erfolgreich.
- Das neue Microtekmodell ScanMaker E3PLUS ist in der Testphase.
(siehe Übersicht für Einzelheiten)
- Microtek V300, 330 und 630
Diese Scannermodelle sollten nun auch unterstützt werden, da sie
laut Programmierdokumentation mit dem Microtek E3PLUS verwandt
sind.
V3.10 17 April 1998
- Der erste Versuch in der Unterstützung des Microtek 330.
Die Scangeschwindigkeit hängt sehr stark vom verwendeten SCSI Host
Adapter ab.
Dieses Scannermodell kann bei kritischen SCSI Host Adaptern zum
Aufhängen des SCSI Busses (stehenbleiben des Rechners) führen.
V3.11 24 May 1998
- Unterstützung des neuen Highscreen HighScan II (Microtek) und
der neuesten Version des Microtek E3Plus
V4.0 19 June 1998
- Lokalisierung von ScanTek.
Unterstützte Sprachen: english, deutsch, dansk
- Neue email Addresse: scantek@gmx.de, wzoehner@gmx.de
V4.1 29 August 1998
- Vollständige Unterstützung der Microtek 630, 330 und des
Highscreen Highscan II
- Farbkorrekturtabellen werden nun unterstützt
- Schnellere Vorschaufunktion bei den neuen Microtekscannern
- ScanTek Supporthomepage ist umgezogen nach
http://www.users.odn.de/~odn05111/scantek.html
- Erweiterte Bildschirmmodusverwaltung bei Programmstart
V4.2 9 September 1998
- Kataloge zur Lokalisierung werden nun korrekt erneuert
- Keine Farbverfälschungen mehr, wenn Farbkorreturtabellen bei
Microtek 630, 330 und Highscreen Highscan II deaktiviert sind
V4.3 6 Dezember 1998
- Unterstützung des Durchlichtaufsatzes und Steuerung der Lampen bei
Microtek 63x, 33x and compatible Highscreen HighScan Scannermodellen
V4.4 3 February 1999
- Verbesserte Surfsquirrel SCSI Unterstützung. Neue Microtekscanner
arbeiten nun auch nach Aktivierung des Surfsquirrel Workarounds.
Problematische SCSI Hostadapter könnten nun ebenfalls funktionieren.
V4.5 3 May 1999
- Ungetestete Unterstützung für neuen Microtek ScanMaker X6
V4.6 27 January 2002
- Better support for ScanMaker 45t
- Dokumentation update (Homepage and eMail)
- ScanTek support homepage has been moved to
http://www.zoehner.de/scantek.html
|
Wenn Sie Anregungen oder Fragen zu ScanTek haben, dann schreiben Sie doch an
scantek@gmx.de |
|
Copyright 1996/97/98/2002 by Waldemar Zöhner V1.1