Overview
The ScanTek scanner driver has the following features:
1. Support of the following SCSI Microtek scanner models:
MICROTEK IISP, MICROTEK II, HIGHSCREEN Flatbed Color IIs,
ScanMaker E3, ScanMaker 35t, ScanMaker E6,
Highscreen PerfectScan, older Highscreen HighScan
Microtek ScanMaker 636, 336 and x6 (old model)
Microtek E3PLUS, V300, 330, 630 and new Highscreen HighScan
This new scanner model can be used in black&white, grey scale
and color scanning.
The download of color lookup tables (gamma curves) is now
supported.
Color scan images can contain a shifted segment, if the image
data is written to a harddisk on the same SCSI host adapter.
The image data should be written to a harddisk on another SCSI
host adapter or to a IDE harddisk.
Support of the following SCSI Mustek Paragon scanner models:
Three Pass Scanners:
Paragon 6000CX, 8000CX (not tested), 12000CX all should work
One or Single Pass Scanners:
Paragon 6000SP, 8000SP, 12000SP (now supported) all should work
Paragon 6000CZ, 8000CZ (not tested)
Paragon 600IISP, 800IISP
The following scanner models are in the development phase:
ScanMaker X6 (new model)
The following scanner models are recognized but not fully supported:
Mustek ScanExpress 12000SP
Mustek Paragon 1200IIISP (caution: III -> version 3)
Color scanning is only successfull at resolutions of 150, 300,
600 and 1200 dpi.
Grey scale scanning is possible.
If the image to be scanned exceeds the scan buffer size than
the image is corrupt. This effect is independent from the
scan mode.
The scanning quality is also (!) dependent from the used
SCSI host adapter.
The ScanExpress or Paragon 12000IIISP scanner models are
not recommended for ScanTek.
At least until sometimes in the future the corresponding
Mustek SCSI programming documentation for these new models
is available. I think this might be a Millenium projekt.
The following scanner models are not supported by now:
All remaining Mustek ScanExpress and Paragon IIISP models.
The following scanner models are not supported:
Canon, Epson, HP, Umax and any parallelport scanner.
Attention: In recent times Mustek has changed the scanner firmware.
I urge you to test Mustek scanners with your Amiga
configuration before buying it.
Mustek scanners have a critical SCSI interface. It
was reported to me that these scanners may not work
with the A2091 and A3000(T) internal SCSI interface.
It is possible that these scanners do not work with
other SCSI host adapters, either.
But the Mustek 6000CX and Paragon MFS-12000SP work in
combination with an Oktagon SCSI host adapter.
Be sure to disable reselection for Mustek scanners
on your SCSI host adapter. Otherwise your system may
not boot.
2. Support of black/white, built-in halftone (dither), one-pass-color-scan,
three pass color scan, grey, red, green and blue scan.
3. Individual setting of resolution, scanning frame, contrast, shadow,
midtone, highlight, exposure time and scanning speed for download to the
scanner.
4. Download of a color look up table (gamma correction table ) to the scanner
supported.
5. Scanning to IFF File of 1, 8 or 24 bit color depth. The maximum size of
the scanned image is independent from the RAM size. After the scanning
process it is possible to start an external program.
6. GUI for preview and configuration of the driver. You need Kickstart 2.04
but Kickstart 3.0 is recommended.
7. Sizeable preview window in black/white or grey scale. Color preview
on Cybergraphix screens (15, 16 or 24 bit necessary).
There are much more skilled programs to view and manipulate the scanned
images in color. (A tool like ADPRO, IMAGE FX or so is needed, if you
want to do sophisticated postproduction)
8. ARexx support
9. Screenmode requester to define custom screen for working. The actual public
screen is supported as well
10. Configurable SCSI device and SCSI ID. The driver supports only SCSI
connectable scanners.
11. The driver is tested with the following SCSI drivers: oktagon.device and
gvpscsi.device V4.5.
12. ScanTek is written using SAS C 6.58.
13. ScanTek is SHAREWARE.
14. The non registered version of ScanTek is a full working version, but all
scanned images have black lines to motivate you to register.
Additionally the maximum size of the preview is restricted.
|
Do you have any suggestions or questions about ScanTek then email to
scantek@gmx.de |
|
Copyright 1996/97/98/2002 by Waldemar Zöhner V1.1